Hardware Installation Guide for the Cisco 4000 Series  Integrated Services Router
OL-32185-02
Chapter 2      Cisco 4000 Series ISRs Preinstallation
  Router Environmental Requirements
Router Environmental Requirements
Cisco  4451-X ISRs can be placed on a desktop or installed in a rack. The location of your router and 
the layout of your equipment rack or wiring room are extremely important considerations for proper 
operation. Equipment placed too close together, inadequate ventilation, and inaccessible panels can 
cause malfunctions and shutdowns, and can make maintenance difficult. Plan for access to both front 
and rear panels of the router. 
When planning your site layout and equipment locations, refer to the “General Site Requirements” 
section on page 2-7, section. If you are currently experiencing shutdowns or an unusually high number 
of errors with your existing equipment, these precautions and recommendations may help you isolate the 
cause of failure and prevent future problems.
• Ensure that the room where your router operates has adequate air circulation. Electrical equipment 
generates heat. Without adequate air circulation, ambient air temperature may not cool equipment 
to acceptable operating temperatures. 
• Always follow ESD-prevention procedures described in the “Prevent Electrostatic Discharge 
Damage” section on page 2-7 to avoid damage to equipment. Damage from static discharge can 
cause immediate or intermittent equipment failure.
• Ensure that the chassis cover and module rear panels are secure. All empty network module slots, 
interface card slots, and power supply bays must have filler panels installed. The chassis is designed 
to allow cooling air to flow within it, through specially designed cooling slots. A chassis with 
uncovered openings permits air leaks, which may interrupt and reduce the flow of air across internal 
components.
• Baffles can help to isolate exhaust air from intake air, which also helps to draw cooling air through 
the chassis. The best placement of the baffles depends on the airflow patterns in the rack, which can 
be found by experimenting with different configurations.
• When equipment installed in a rack (particularly in an enclosed rack) fails, try operating the 
equipment by itself. Power off other equipment in the rack (and in adjacent racks) to allow the router 
under test a maximum of cooling air and clean power.