NTPIP:0
AltNTPIP:0
DNS1IP:0.0.0.0
DNS2IP:0.0.0.0
UDPTOS:0xA0
RingOnOffTime:2,4,25
DialTone:2,31538,30831,1380,1740,1,0,0,1500
BusyTone:2,30467,28959,1191,1513,0,4000,4000,0
ReorderTone:2,30467,28959,1191,1513,0,2000,2000,0
RingBackTone:2,30831,30467,1943,2111,0,16000,32000,0
CallWaitTone:1,30831,0,5493,0,0,2400,2400,4800
AlertTone:1,30467,0,5970,0,0,480,480,1920
DialPlan:*St4-|#St4-|911|1>#t8.r9t2-|0>#t811.rat4-|^1t4>#.-
IPDialPlan: 1
CallCmd:Af;AH;BS;NA;CS;NA;Df;EB;Ff;EP;Kf;EFh;HQ;Jf;AFh;HQ;I*67;gA*82;fA#90v#;OI;H#72v#;bA#
74v#;cA#75v#;dA#73;eA*67;gA*82;fA*70;iA*69;DA*99;xA;Uh;GQ;
SIPPort:5060
SIPRegOn:0
SIPRegInterval:120
MaxRedirect:5
OutBoundProxy:0
NatServer:0
NatTimer:0
NPrintf:0
TraceFlags:0x00000000
EchoIP:192.168.2.9
SigTimer:0x01418564
OpFlags:0x2
VLANSetting:0x0000002b
FeatureTimer:0x00000000
The sections that follow describe these parameters.
User Interface (UI) Parameter
This section contains only one parameter—UIPassword.
UIPassword
Description
This parameter controls access to web page or voice configuration menu interface. To set a password,
enter a value other than zero. To have the user prompted for this password when attempting to perform
a factory reset or upgrade using the voice configuration menu, see the “OpFlags” section on page 5-33.
To clear a password, change the value to 0.
You cannot recover a forgotten password unless you reset the entire configuration of the Cisco ATA (see
the “Resetting the Cisco ATA to Factory Default Values” section on page 3-18). If you forget a password,
you can contact your Cisco representative.
Note When UIPassword contains letters, you cannot enter the password from the telephone keypad.
Value Type
Alphanumeric string

Table of Contents

Other manuals for Cisco ATA 186

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ATA 186 and is the answer not in the manual?

Cisco ATA 186 Specifications

General IconGeneral
Operating Temperature32°F to 104°F (0°C to 40°C)
ProtocolSIP, H.323
Network Interface10/100BASE-T Ethernet
Audio Codec SupportG.729a, G.723.1
Power Supply5V DC
Weight0.23 kg (0.5 lb)
Relative Humidity10 to 90% noncondensing
Ports2 RJ-11 FXS ports