Before You Begin
Follow these guidelines to enable the readiness check on the switch:
•
The readiness check is typically used before 802.1x is enabled on the switch.
•
If you use the dot1x test eapol-capable privileged EXEC command without specifying an interface,
all the ports on the switch stack are tested.
•
When you configure the dot1x test eapol-capable command on an 802.1x-enabled port, and the link
comes up, the port queries the connected client about its 802.1x capability. When the client responds
with a notification packet, it is 802.1x-capable. A syslog message is generated if the client responds
within the timeout period. If the client does not respond to the query, the client is not 802.1x-capable.
No syslog message is generated
•
When you configure the dot1x test eapol-capable command on an 802.1x-enabled port, and the link
comes up, the port queries the connected client about its 802.1x capability. When the client responds
with a notification packet, it is 802.1x-capable. A syslog message is generated if the client responds
within the timeout period. If the client does not respond to the query, the client is not 802.1x-capable.
No syslog message is generated
•
The readiness check can be sent on a port that handles multiple hosts (for example, a PC that is connected
to an IP phone). A syslog message is generated for each of the clients that respond to the readiness check
within the timer period.
SUMMARY STEPS
1.
enable
2.
configure terminal
3.
dot1x test eapol-capable [interface interface-id]
4.
dot1x test timeout timeout
5.
end
6.
show running-config
7.
copy running-config startup-config
DETAILED STEPS
PurposeCommand or Action
Enables privileged EXEC mode. Enter your password if
prompted.
enable
Example:
Switch> enable
Step 1
Enters the global configuration mode.configure terminal
Example:
Switch# configure terminal
Step 2
Catalyst 2960-X Switch Security Configuration Guide, Cisco IOS Release 15.0(2)EX
OL-29048-01 301
Configuring IEEE 802.1x Port-Based Authentication
Configuring 802.1x Readiness Check

Table of Contents

Other manuals for Cisco Catalyst 250 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 250 Series and is the answer not in the manual?

Cisco Catalyst 250 Series Specifications

General IconGeneral
BrandCisco
ModelCatalyst 250 Series
CategorySwitch
LanguageEnglish

Related product manuals