2-86
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
PM Messages
has been configured with the power inline never interface configuration command. [chars] is the
port where the threshold was exceeded. The first [chars] is the error, and both the second and third
[chars] are the affected interface.
Recommended Action On non-PoE switches, copy the message exactly as it appears on the console or
in the system log. Research and attempt to resolve the error by using the Output Interpreter. Use the
Bug Toolkit to look for similar reported problems. On PoE switches, remove the device or configure
the port by entering the power inline auto, shutdown, and no shutdown interface configuration
commands. If you still require assistance, open a case with the TAC, or contact your Cisco technical
support representative, and provide the representative with the gathered information. For more
information about these online tools and about contacting Cisco, see the
“Error Message Traceback
Reports” section on page 1-7.
Error Message PM-4-ERR_DISABLE_VP: [chars] error detected on [chars], vlan [dec].
Putting in err-disable state.
Explanation The virtual port (that is, the port-VLAN pair) is error-disabled state when it detects a
misconfiguration or misbehavior. If configured, a recovery will be attempted after the configured
retry time (default time is 5 minutes). The first [chars] is the error, and the second [chars] is the port.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7.
Error Message PM-4-ERR_RECOVER: Attempting to recover from [chars] err-disable state
on [chars].
Explanation The port manager is trying to restart an error-disabled interface. The first [chars] is the
error, and the second [chars] is the interface.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7.
Error Message PM-4-ERR_RECOVER_VP: Attempting to recover from [chars] err-disable
state on [chars], vlan [dec].
Explanation The port manager is trying to restart an error-disabled virtual port. The first [chars] is
the error, the second [chars] is the virtual port, and [dec] is the VLAN ID.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or

Table of Contents

Other manuals for Cisco Catalyst 3750-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3750-X and is the answer not in the manual?

Cisco Catalyst 3750-X Specifications

General IconGeneral
Switching Capacity160 Gbps
Stacking Bandwidth64 Gbps
Max Stacking Units9
Layer SupportLayer 2 and Layer 3
Form FactorRack-mountable
DRAM256 MB
Flash Memory64 MB
ModelCisco Catalyst 3750-X Series
Ports24 or 48 10/100/1000 Ethernet ports
Uplink Interfaces4 SFP or 2 SFP+
FeaturesStackWise Plus, EnergyWise
ImageIP Base or IP Services
Operating Temperature0 to 40°C
Operating Humidity10 to 85% noncondensing