Page #150 background image
SpecificationItem
-40° to 167°F (-40° to 75°C)Nonoperating and storage
temperature
Hot to cold—at a maximum rate of 86°F (30°C) per hour
Cold to hot—at maximum rate of 204.8°F (96°C) per hour
Thermal transition
Operating, nonoperating and storage —10 to 95 percentHumidity (RH), ambient
(noncondensing)
-60 to 3000mAltitude (operating and
nonoperating)
LpAD—57 dBA
LwAD—no greater than 7.2 Bels
This is with four power supply modules installed and delivering 50 percent of
rated output power; measured according to International Organization for
Standardization (ISO) 7779 and declared according to ISO 9296.
Sound pressure level
(LpAD) and sound power
level (LwAD)
Chassis (airflow direction when facing the front of the chassis)
Standard Rack Mount (With or without shelf brackets)—Right to left
NEBS-Compliant Rack Mount—Front to back
Power supply—Front to back
Airflow
Operating—5G 11ms (Half-sine)
Nonoperating and storage— 15G 11ms (Half-sine)
Shock
Operating— 0.15G (10Hz-500Hz)
Nonoperating and storage— 0.8G (10Hz-500Hz)
Sine Vibration
SlopeAcceleration Spectral
Density
Spectral Break Point
Frequencies
Random Vibration
(Operating)
6 db /octave-2.5 5 Hz
-0.1 [(m/s²)²]/Hz
(0.001 g²/Hz)
5 100 Hz
24 db /octave-100 200 Hz
Cisco Catalyst 9400 Series Switches Hardware Installation Guide
144
Specifications
Catalyst 9404R Switch Chassis Specifications

Table of Contents

Other manuals for Cisco Catalyst 9400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 9400 Series and is the answer not in the manual?

Cisco Catalyst 9400 Series Specifications

General IconGeneral
SeriesCatalyst 9400 Series
Form FactorRack-mountable
Operating SystemCisco IOS XE
Uplink Options40G and 100G uplinks
StackingNot supported
Layer SupportLayer 2 and Layer 3
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Humidity5% to 90% noncondensing
Power Supply OptionsAC and DC power supplies
RedundancyPower supply, supervisor engine
Modular Slots7 or 10
MAC Address Table Size256, 000
Security FeaturesACLs, TrustSec, MACsec
ManagementCLI, SNMP, NETCONF, RESTCONF, Cisco DNA Center