Table 21: Power Requirements and Heat Dissapation - Supervisor Module
Heat Diss. in
BTU / hr.
Current @
240V
Current @
180V
Current @
120V
Current @
90V
DC-Output in
Watts
(Power
Requested)
AC-Input
Power in
Watts
(Power
Allocated)
PID
15161.852.473.704.94400444C9400-SUP-1
15161.852.473.704.94400444C9400-SUP-1XL
15401.882.513.765.0400444C9400-SUP-1XL-Y
Table 22: Power Requirements and Heat Dissipation Switching Modules
Heat Diss. in
BTU / hr.
Current @
240V
Current @
180V
Current @
120V
Current @
90V
DC-Output in
Watts
(Power
Requested)
AC-Input
Power in
Watts
(Power
Allocated)
PID
2460.300.400.600.806572C9400-LC-48T
2460.300.400.600.806572C9400-LC-48U
7580.931.231.852.47200222C9400-LC-24XS
9101.111.482.222.96240267C9400-LC-48UX
6440.791.051.572.10170189C9400-LC-48S
4550.560.741.111.48120133C9400-LC-24S
2460.300.400.600.806572C9400-LC-48P
2460.300.400.600.806572C9400-LC-48H
Weight Specifications
The total weight of a fully configured chassis will depend on the type of chassis, the number of modules, and
power supplies installed. Use the corresponding weights in the tables below to arrive at the total chassis weight
for your hardware configuration.
Chassis Weights
Weight (Chassis with Fan Tray)PID (add = for spare)
39.0lbs (17.2 kgs)C9404R
63.0 lb (28.58 kg)C9407R
Cisco Catalyst 9400 Series Switches Hardware Installation Guide
158
Specifications
Weight Specifications

Table of Contents

Other manuals for Cisco Catalyst 9400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 9400 Series and is the answer not in the manual?

Cisco Catalyst 9400 Series Specifications

General IconGeneral
SeriesCatalyst 9400 Series
Form FactorRack-mountable
Operating SystemCisco IOS XE
Uplink Options40G and 100G uplinks
StackingNot supported
Layer SupportLayer 2 and Layer 3
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Humidity5% to 90% noncondensing
Power Supply OptionsAC and DC power supplies
RedundancyPower supply, supervisor engine
Modular Slots7 or 10
MAC Address Table Size256, 000
Security FeaturesACLs, TrustSec, MACsec
ManagementCLI, SNMP, NETCONF, RESTCONF, Cisco DNA Center