Loading...
RangeMeasure
5 percent to 95 percent noncondensingRelative humidity
Up to 15,000 feet (4572 m) with no temperature derating
Up to 40,000 feet (12,192 m) with temperature derating down to
25° C
Operating altitude
Up to 40,000 feet (12,192 m)Storage altitude
1.75 in (4.4 cm) clearance top, sides, and bottomThermal spacing
50G at 11ms, half sine and 200G ar 2.11ms, half sineOperational shock
65 to 80G at 9ms, trapezoidalNonoperational shock
The safety certifications apply only to ambient temperatures under 140 F (60 C).
Note
Table 22: Switch Power Requirements
RequirementMeasure
PWR-RGD-AC-DC-H:
100 to 240 VAC, 50 to 60 Hz
100 to 250 VDC
PWR-RGD-AC-DC-250:
100 to 240 VAC, 50 to 60 Hz
100 to 250 VDC
PWR-RGD-LOW-DC-H:
4 to 60 VDC
Nominal input voltage
PWR-RGD-AC-DC-H:
90 to 264 VAC, 50 to 60 Hz
90 to 300 VDC
PWR-RGD-AC-DC-250:
90 to 264 VAC, 50 to 60 Hz
90 to 300 VDC
PWR-RGD-LOW-DC-H:
18 to 75 VDC
Supported input voltage operating range