Beacon is turned off
Belongs to san-port-channel 200
Trunk vsans (admin allowed and active) (1,55,100,200-202,204)
Trunk vsans (up) (100,202)
Trunk vsans (isolated) (204)
Trunk vsans (initializing) (1,55,200-201)
5 minutes input rate 0 bits/sec,0 bytes/sec, 0 frames/sec
5 minutes output rate 0 bits/sec,0 bytes/sec, 0 frames/sec
406 frames input,40164 bytes
0 discards,0 errors
0 invalid CRC/FCS,0 unknown class
0 too long,0 too short
192 frames output,14364 bytes
0 discards,0 errors
1 input OLS,1 LRR,5 NOS,0 loop inits
3 output OLS,1 LRR, 4 NOS, 0 loop inits
500 transmit B2B credit remaining
0 low priority transmit B2B credit remaining
Last clearing of "show interface" counters :never
Verifying FC NPV Traffic Management
To display the FC NPV traffic map, enter the show npv traffic-map command.
switch# show npv traffic-map
NPV Traffic Map Information:
----------------------------------------
Server-If External-If(s)
----------------------------------------
fc1/3 fc1/10,fc1/11
fc1/5 fc1/1,fc1/2
----------------------------------------
To display the FC NPV internal traffic details, enter the show npv internal info traffic-map command.
Verifying Disruptive Load Balancing
To display the disruptive load-balancing status, enter the show npv status command:
switch# show npv status
npiv is enabled
disruptive load balancing is enabled
External Interfaces:
====================
Interface: fc2/1, VSAN: 2, FCID: 0x1c0000, State: Up
...
FC NPV Core Switch and FC NPV Edge Switch Configuration
Example
Before You Begin
This section demonstrates how to configure FC NPV core and edge switches.
Procedure
Step 1
Procure and install the FC_PORT_ACTIVATION_PKG and FCOE_NPV_PKG licenses.