EasyManuals Logo

Cisco N9K-C93180YC-FX User Manual

Cisco N9K-C93180YC-FX
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
Configuring SAN Port Channels
SAN port channels are created with default values. You can change the default configuration just as any other
physical interface.
If the following requirements are not met, a SAN port channel error is detected:
Each switch on either side of a SAN port channel must be connected to the same number of interfaces.
Each interface must be connected to a corresponding interface on the other side.
Links in a SAN port channel cannot be changed after the port channel is configured. If you change the
links after the port channel is configured, be sure to reconnect the links to interfaces within the port
channel and reenable the links.
If all three conditions are not met, the faulty link is disabled. Enter the show interface command for that
interface to verify that the SAN port channel is functioning as required.
Note
SAN Port Channel Guidelines and Limitations
The number of SAN port channels and virtual FC port channels, together, can be only 8 on the Cisco
Nexus 9000 Series switch.
The maximum number of FC interfaces that can be combined into a SAN port channel is limited to 16.
The default channel mode on Cisco Nexus 9000 Series switches for SAN port channels is active; this
cannot be changed.
Creating a SAN Port Channel
This section explains how to create a SAN port channel.
Procedure
Step 1
switch# configuration terminal
Enters the global configuration mode.
Step 2
switch(config)# interface san-port-channel channel-number
Creates the specified SAN port channel using the default mode (on). The SAN port channel number is in the
range of 1 to 256
The following example shows the SAN port channel creation:
switch(config)# interface san-port-channel 1
switch(config-if)#
Cisco Nexus 9000 Series NX-OS FC NPV Configuration Guide
5
Configuring N Port Virtualization
Configuring SAN Port Channels

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco N9K-C93180YC-FX and is the answer not in the manual?

Cisco N9K-C93180YC-FX Specifications

General IconGeneral
Product ModelN9K-C93180YC-FX
ManufacturerCisco
CategorySwitch
Switching Capacity3.6 Tbps
Forwarding Rate2.7 bpps
Jumbo Frames9216 bytes
VLAN IDs4096
Rack Units1 RU
AirflowFront-to-back
Form FactorRack-mountable
Operating SystemCisco NX-OS
Ports48 x 1/10/25-Gbps SFP+ and 6 x 40/100-Gbps QSFP28
Routing ProtocolBGP, IS-IS, OSPF, RIP, EIGRP
FeaturesVXLAN, EVPN
Compliant StandardsIEEE 802.1Q, IEEE 802.1p, IEEE 802.3ad
LatencySub-microsecond
Power SupplyInternal power supply - hot-plug

Related product manuals