9-18
Cisco SCE8000 Installation and Configuration Guide, Rel 3.1.7
OL-16478-03
Chapter 9 Removal and Replacement Procedures
Removing and Replacing Modules
Figure 9-13 Ejector Lever Closure
Step 11
Tighten the two captive installation screws on the module.
Note Make sure the ejector levers are fully closed before tightening the captive installation screws.
Removing a Module
Before you remove an SCE8000-SCM, you should first save the current configuration, if the current
configuration should be preserved and duplicated on the new SCE8000-SCM-E. (Use the copy
running-config startup-config command.) This step saves time when bringing the module back online,
if the configuration will remain the same or similar. You can recover the configuration by downloading
it from the server to the nonvolatile memory of the SCE8000-SCM-E.
Tip When you install a new SCE8000-SCM-E, check the factory default configuration; you might need to
reconfigure the system to your requirements. You can reconfigure the SCE8000-SCM-E manually, or if
you previously uploaded the original configuration to a server, you can download it to the new
SCE8000-SCM-E.
Step 1 At the SCE# prompt, type reload shutdown and press Enter to power down the Cisco SCE8000
platform before installing or removing any module.
Step 2 Verify that the captive installation screws on all of the modules in the chassis are tight. This step assures
that the space created by the removed module is maintained.
270909
FA
N
STATUS
S
C
M
1
S
C
M
2
S
IP
3
4
SC
E
8
00
0
-
FA
N
S
Y
STE
M
PO
W
E
R
O
P
T
IC
AL
BY
PAS
S
S
T
A
T
U
S
A
U
X
PORT
2
L
IN
K
A
C
T
I
V
E
M
A
ST
E
R
S
C
E
8
000
E
X
T
E
N
DE
D
SE
R
V
I
C
E
C
O
NT
R
OL
M
O
DU
L
E
O
PT
I
C
AL
BY
P
ASS
O
PT
IC
AL
B
Y
P
ASS
C
O
N
S
O
L
E
1
0
1
0
0
100
0
L
IN
K
A
C
TI
V
E
POR
T
1
A
C
A
B
C
D
B
D
ST
ATU
S
C
T
R
L
O
P
B
-
S
C
E
8
K
-
M
M
O
P
TIC
AL
B
Y
P
A
S
S
1
TX
R
X
TX
R
X
TX
R
X
T
X
R
X
A
C
A
B
C
D
B
D
S
TA
TU
S
CT
R
L
O
PB
-
SCE
8K
-MM
O
PT
I
C
A
L
B
YPA
S
S
2
T
X
RX
TX
R
X
T
X
RX
TX
RX
S
Y
ST
E
M
PO
W
E
R
O
P
T
IC
A
L
BY
PAS
S
S
T
A
T
U
S
AUX
POR
T
2
1
0
10
0
10
00
LINK
A
C
TI
VE
M
A
ST
ER
S
C
E
8
000
E
X
T
E
N
DE
D
SE
RV
I
C
E
C
O
NT
R
OL
M
O
DU
L
E
SCE80
0
0
-
S
C
M-
E
SCE80
0
0
-
S
C
M-
E
SC
E
8
000-
S
IP
C
O
N
S
O
L
E
10
1
00
100
0
L
IN
K
A
C
TI
V
E
POR
T1
O
PT
I
C
AL
BY
P
ASS
O
P
TI
CAL
BY
P
A
S
S
STAT
U
S
ACTIVE/L
I
N
K
S
P
A
-
1
X
10
GE
-
L-
V2
STAT
U
S
ACTI
VE/L
I
N
K
S
P
A
-1
X
10
GE
-
L
-
V2
STAT
U
S
ACT
IVE/
L
I
N
K
S
P
A
-1
X
10
GE
-
L-
V
2
STAT
U
S
ACT
IVE/
L
I
N
K
S
P
A
-
1
X
1
0
G
E
-
L-
V2
1
0
100
1000
Ejector levers flush
with module faceplate