Ensure that you have not enabled the feature set in the specified VDC.
SUMMARY STEPS
1.
configure terminal
2.
vdc vdc_ID
3.
no allow feature-set fex
4.
end
DETAILED STEPS
PurposeCommand or Action
Enters configuration mode.configure terminal
Example:
switch# configure terminal
switch(config)#
Step 1
Specifies a VDC and enters VDC configuration mode.
vdc vdc_ID
Example:
switch(config)# vdc 1
Step 2
Disallows the feature set in the VDC. You cannot disallow a feature
set that is enabled in the specified VDC.
no allow feature-set fex
Example:
switch(config-vdc)# no allow feature-set
fex
Step 3
By default, the installed Fabric Extender feature set is allowed in all
VDCs on the device. You can disallow a feature set in a specific
VDC. Subsequently, you can change the status back to allowed with
the allow feature-set fex command.
Exits VDC configuration mode and returns to EXEC mode.end
Example:
switch(config-vdc)# end
switch#
Step 4
Associating a Fabric Extender to a Fabric Interface
A FEX is connected to its parent device through a port channel. By default, the parent device does not allow
the attached Fabric Extender to connect until it has been assigned a FEX-number and is associated with the
connected interface.
You must have installed and enabled the Fabric Extender features with the install feature-set fex and
feature-set fex commands before you can configure and use a Fabric Extender that is connected to the
parent switch.
Note
Cisco Nexus 2000 Series NX-OS Fabric Extender Software Configuration Guide
16 OL-25816-02
Configuring the Fabric Extender
Associating a Fabric Extender to a Fabric Interface

Table of Contents

Other manuals for Cisco SGE2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SGE2000 and is the answer not in the manual?

Cisco SGE2000 Specifications

General IconGeneral
Jumbo Frame Support9KB
VLANsUp to 256
ManagementWeb-based, SNMP, CLI
StandardsIEEE 802.3, 802.3u, 802.3ab, 802.3z, 802.3x, 802.1D, 802.1Q, 802.1p, 802.1w
Dimensions440 x 44 x 257 mm
Power Supply100 to 240V AC, 50-60 Hz
Operating Temperature0°C to 40°C
Storage Temperature-20 to 70°C (-4 to 158°F)
Humidity10% to 90% non-condensing
Weight3.2 kg