When using SAS/SATA drives, the eight drives must be all SAS/SATA; no mixing with NVMe drives
is allowed.
When populating drives, add drives to the lowest-numbered bays first.
Keep an empty drive blanking tray in any unused bays to ensure proper airflow.
You can mix SAS/SATA hard drives and SAS/SATA SSDs in the cage. However, you cannot configure
a logical volume (virtual drive) that contains a mix of hard drives and SSDs. That is, when you create a
logical volume, it must contain all SAS/SATA hard drives or all SAS/SATA SSDs.
See also 4K Sector Format SAS/SATA Drives Considerations, on page 20.
Note
Figure 11: Internal Drive Module Bays (Top View)
Rear SAS/SATA Drive Requirements
Observe these requirements:
The optional, rear drive module (UCSC-C480-8HDD).
The rear drive module requires minimum Cisco IMC and BIOS 3.1(3) or later.
The rear drive-bay module must have air-diffuser UCSC-DIFF-C480M5 installed when SAS/SATA
drives are installed.
Maintaining the Server
23
Maintaining the Server
Rear SAS/SATA Drive Requirements

Table of Contents

Other manuals for Cisco UCS C480 M5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C480 M5 and is the answer not in the manual?

Cisco UCS C480 M5 Specifications

General IconGeneral
BrandCisco
ModelUCS C480 M5
CategoryServer
LanguageEnglish

Related product manuals