- 142 -
(2) 2nd byte (Error occurrence information)
2
No Mechanism error occurred.
No BM detection error occurred.(
selected)
No presenter error occurred. (only when presenter function is
00H 0
A Mechanism error occurred.
A BM detection error occurred.(only when BM paper is selected)
A presenter error occurred (
only when presenter function is
enabled.)
04H 4
3
Auto cutter error not occurred
Auto cutter error occurred
5
Unrecoverable error not occurred
Unrecoverable error occurred
6
Auto recovery error not occurred
Auto recovery error occurred
*Bit 2: In case of MSW3-8=ON, i t is generated by cover-open.
At BM/Label model, it is generated by BM/Label-error.
At presenter model, it is generated at presenter error.
*Bit 3: If this error occurred because of a paper jam, for example, remove the cause of the error, and then
DLE ENQ n (1 n 2) can be used to recover from the error. However, it is not possible to recover from
any error due to a circuit problem (e.g., broken wire).
*Bit 6: If a head overheat error is detected, the printing is stopped until the head temperature falls. At this
time, bit 6 = 1.
(3) 3rd byte (Paper Sensor information)
0, 1
Paper found by Paper Near-end Sensor
Paper not found by Paper Near-end Sensor
2, 3
Paper found by Paper-end Sensor
Paper not found by Paper-end Sensor