- 480 - 
4.2.6 MSW6 
●MSW6-1:  Mode to use with the driver 
 [Outline]   Selects the valid/invalid of mode to use with the driver 
 
Mode to use with the driver 
 
ON (1) OPERATION: FAULT signal is not output in the error condition to parallel port.. 
   ASB is valid at power on. (Same behavior as GS a n command and n = 15) 
OFF (0) OPERATION: FAULT signal is output in the error condition to parallel port.. 
  ASB is invalid at power on. (Same behavior as GS a n command and n = 0) 
 
Remarks: Function below is added for the models  after CT-S251/CT-S8xxII/CT-S6xxII. 
Settings of automatic buffer clearing function at printer error are as follows.  
・ON(1) OPERATION  Automatic buffer clear at error detection is enabled. 
・OFF(0) OPRATION  Automatic buffer clear at error detection is disabled. 
 
●MSW6-2:  Character space mode 
 [Outline]   Selects the valid/invalid of mode to have right space for each character 
 
 
ON (1) OPERATION: Default of right space of each character is “0”. 
Same behavior as ESC SP n command and parameter n = 0. 
OFF (0) OPERATION: Default of right space of each character is “1”. 
  The right vertical dot column in character composition matrix is repeated in the additional right space. In this mode, 
number of columns for font B and C is decreased by 1 - 4. 
 
●MSW6-3:  USB Power Save 
[Outline]   Select the valid/invalid of USB Power save mode. 
 
 
When printer is connected to the host through USB, if PC power is turned off or USB cable is 
disconnected, printer enters special power save mode. This is USB Power save mode. 
ON (1) OPERATION: When the condition is satisfied, printer enters the USB Power save mode. 
OFF (0) OPERATION: Even the condition is satisfied, printer does not enter USB Power save mode.