- 251 -
CT-S310II
• a=202: Controls input buffer full Busy with the value selected by
(nL+nH×256) and controls Busy with output/cancel timing
(remaining capacity).
(nL+nH×256)
When Input Buffer
Capacity “Small” is Set
When Input Buffer
Capacity 4K Bytes (Large)
is Set
Output Cancel Output Cancel
1(Default)
16
26
128
256
2
16
40
128
512
3
30
50
72
256
4
30
60
72
512
• XON/XOFF is also output by the establishment of conditions.
• Ignores the data received when input buffer idle capacity is 0.
a=212: Selects DMA (Direct Memory Access) control of serial
communication specified by (nL+nH×256).
(nL+nH×256)
DMA control
1
Invalid
2(Default)
Valid
a=213: Selects the flow control specified by (nL+nH×256) when virtual
COM is set.
(nL+nH×256)
Flow control
1(Default)
PC setting
2
DTR/DSR
3
XON/XOFF
a=214: Select the enable/disable of Kanji specified by (nL+nH×256)
(nL+nH×256)
Kanji
1
Invalid(OFF)
2(Default)
Valid(ON)
a=216: Select the JIS/Shift JIS specified by (nL+nH×256)
(nL+nH×256)
JIS/Shift JIS
1(Default)
JIS
2
Shift JIS(CP932)
3
Shift JIS(X0213)
a=217: Select the international character set specified by (nL+nH×256)
(nLnH×256)
Int’l Char set
(nLnH×256)
Int’l Char set
1(Default)
U.S.A.
10
Norway
2
France
11
Denmark II
3
Germany
12
Spain II
4
U.K.
13
Latin America
5
Denmark I
14
Korea
6
Sweden
15
Croatia
7
Italy
16
P.R. China
8
Spain I
17
Vietnam
9
Japan