EasyManua.ls Logo

Citizen CT-E351 - Page 318

Citizen CT-E351
512 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Support
model
CT-S280 CT-S300 CT-S2000 CT-S4000 CT-S251 CT-D150/E351
CT-S281
CT-S310
CT-S801/851
CT-S601/651
CT-P29x series
CT-S310II
CT-D151/E651
- 317 -
CT-S801/CT-S851
• a=116: When kind of paper is specified
Setting Status
Sending Data
Stored
Value
Paper
1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
1
Single-color paper
49(“1”)
-
-
-
-
2
2-color paper
50(“2”)
53(“5”)
55(“7”)
-
-
a151: When Bluetooth Security/Connect Device is specified. [CT-S801II, CT-S851II]
Setting Status Sending Data
Stored
Value
Security /
Connect Device
1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
1
Low / All
49(“1”)
-
-
-
-
2
Middle / All
50(“2”)
-
-
-
-
3
Middle / Paired
51(“3”)
-
-
-
-
4
High / All
52(“4”)
-
-
-
-
5
High / Paired
53(“5”)
-
-
-
-
a155: When Bluetooth Device Scan is specified. [CT-S801II, CT-S851II]
Setting Status
Sending Data
Stored
Value
BT Device Scan 1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
1
No Response
49(“1”)
-
-
-
-
2
Discoverable
50(“2”)
-
-
-
-
a156: When Bluetooth Auto Reconnect is specified. [CT-S801II, CT-S851II]
Setting Status
Sending Data
Stored
Value
Auto Reconnect
1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
1
Invalid
49(“1”)
-
-
-
-
2
Valid
50(“2”)
-
-
-
-
• a=201: When ACK output position is specified
Setting Status
Sending Data
Stored
Value
ACK Output
Position
1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
1
ACK-in-Busy
49(“1”)
-
-
-
-
2
ACK-while-Busy
50(“2”)
-
-
-
-
3
ACK-after-Busy
51(“3”)
-
-
-
-
• a=202: Input buffer full Busy output/cancel timing
Setting Status
Sending Data
Stored
Value
BUSY
Output/Cancel
1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
1
49(“1”)
-
-
-
-
2
50(“2”)
-
-
-
-
3
51(“3”)
-
-
-
-
4
52(“4”)
-
-
-
-
a=212: When DMA (Direct Memory Access) control of serial communication is specified
Setting Status
Sending Data
Stored
Value
DMA control 1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
1
Invalid
49(“1”)
-
-
-
-
2
Valid
50(“2”)
-
-
-
-
a=213: When the flow control of virtual COM is specified.
Setting Status
Sending Data
Stored
Value
Flow control 1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
1
PC setting
49(“1”)
-
-
-
-
2
DTR/DSR
50(“2”)
-
-
-
-
3
XON/XOF
51(“3”)
-
-
-
-

Table of Contents