Citrix ADC MPX
Health Attribute Unit Minimum value Nominal value Maximum value
CPU Fan 0 Speed RPM 1500 ‑NA‑ 7500
CPU Fan 1 Speed RPM 1500 ‑NA‑ 7500
System Fan
Speed
RPM 1500 ‑NA‑ 7500
System Fan 1
Speed
RPM 1500 ‑NA‑ 7500
System Fan 2
Speed
RPM 1500 ‑NA‑ 7500
Fan 0 Speed RPM 1500 ‑NA‑ 7500
CPU 0 Temp Celsius 0 ‑NA‑ 85
CPU 1 Temp Celsius 0 ‑NA‑ 85
Internal Temp Celsius 0 ‑NA‑ 80
Health attributes for the MPX 14000 platform
The following table lists the health attributes for the MPX 14000 platform.
Health Attribute Recommended Range
CPU 0 core (Volts) 0.85–0.91
CPU 1 core Volt 0.85–0.93
Main 3.3 V Supply (Volts) 3.31–3.36
Standby 3.3 V Supply (Volts) 3.26–3.31
+5.0 V Supply (Volts) 4.99–5.06
+12.0 V Supply (Volts) 11.98–12.08
Battery Voltage 3.02–3.12
Internal CPU Vtt Power 0.99–1.01
CPU Fan 0 Speed (RPM) 1875–4350
CPU Fan 1 Speed (RPM) 1875–4200
System Fan Speed (RPM) 1875–4350
System Fan 1 Speed (RPM) 1875–4275
System Fan 2 Speed (RPM) 1875–4200