73
ENGINE
73
COOLING SYSTEM SPECIFICATIONS
Engine type
Capacity
Radiator surface
Pressurisation
Opening of thermostatic regulator
Cooling fan
1st speed
2nd speed
3rd speed
Air con cut-off
Alert
Post cooling
Marking
Information
Sensor
Colour of connector
Tightening (m.daN)
Engines: ES9A - DTE17BTED4
3.0i 24S 2,7 24V
XFV UHZ
11,3 13,2
27 dm
2
1,4 bar
78°C 83°C
1 x 600 W 2 x 150W
FRIC function 97°C or aircon in operation
105°C 101°C or 17 bars in the aircon circuit
105° or 30 bars in the aircon circuit
115°C or 30 bars in the aircon circuit
118°C
6 minutes
11 6
Level of coolant Temperature of coolant Temperature, diesel injection, alert, aircon
Resistance Thermostat Thermostat
Black Blue Grey
1,7 ± 0,4
Angl-C6-page022-82-2005 4/02/05 17:19 Page 73