Electrical Supply
Electrical connections MUST be carried out in accordance with
local regulations. As a minimum Classeq recommends the
following are maintained:
All warewashers are connected via a residual current
device (RCD) or earth leakage protection device.
A means for disconnection that has all poles separation
of more than 3 mm must be incorporated in the fixed
wiring in accordance with wiring rules.
Connect to an equipotential conductor, connection stud
located at rear of the warewasher, this is in addition to
the earthed electrical supply.
Prior to connecting the warewasher, ensure voltage and
supply fuse comply with rating plate.
Electrics
C400 /
C400WS
C500 /
C500WS
Supply 1
220-240V
(1-phase)
13A
2.5 kW
2.5kW
Supply 2
380-415V
(3-phase)
13A
6.5 kW
6.5 kW
Supply 3
220-240V
(1-phase)
30A
6.5 kW
6.5 kW
Supply 4
220-240V
(1-phase)
20A
4.5kW
4.5 kW
Supply Socket (mm)
D400 /
G400
D500 /
G500
Max
position
of
electrical
supply
socket
(mm)
W = width
950
700
H =
height
(max)
1500
1550
Water Inlet
D400 /
G400
D500 /
G500
Temperature range
4 - 55°C
Pressure
0 - 2 bar
Rinse boaster pump
required
2 - 10
bar
No modification
Flowrate
4 l/min
D400 /
G400
D500 /
G500
Water connection
G¾” (¾” BSP)
Maximum
position
of water
supply
(mm)
W =
width
650
600
H =
height
700
650
Waste Outlet
Drainage Dimensions
(mm)
D400 /
G400
D500 /
G500
Drain standpipe
diameter
35
35
W = maximum distance
from warewasher
750
400
Drain pipe height (drain
pump)
0 - 500
0 - 600
4.4 Electrical Connection
4.4.1 Mains cable connection
Prior to connecting
the warewasher,
ensure that the
available electrical
outlet voltage and
the supply fuse
comply with the
rating of the
warewasher. For
the electrical rating of your warewasher refer to the rating plate.
Contact your distributor, a qualified electrician, or Classeq if you
are unsure how to check this.
The electrical supply must incorporate a disconnection device
(circuit breaker / fuse) that complies with local and national
regulations.