07610-004-64-85-A
5
INSTRUCTIONS
INSTALLATION
WATER SUPPLY
CONNECTIONS:
WATER HARDNESS
HIGHER THAN 3 GPG
Before installing machine, check packaging and machine for damage. Damaged
packaging might be an indication of damage to the machine. If there is any type
of damage to both packaging and machine, do not throw away the packaging. The
machine has been inspected at the factory before shipping and is expected to arrive
in new, undamaged condition. However, rough handling by carriers or others might
result in damage to the machine while in transit. If this occurs, do not return machine to
the manufacturer. Instead, contact the carrier and ask them to send a representative
to the site to inspect the damage and request that an inspection report be completed.
Contact the carrier within 48 hours of receiving the machine as well as the dealer that
sold you the machine.
The machine should be unpacked and removed from the pallet before installing. Open
the front door and remove all materials from inside. Once unpacked, verify there are no
missing parts. If a part is missing, contact the manufacturer immediately.
All plumbing connections must adhere to local, state, territorial, and national codes.
The installing plumber is responsible for ensuring the incoming water lines are ushed
of debris before connecting to the machine. Note that chips and materials from cutting
processes can become lodged in the solenoid valves and prevent them from opening
or closing. Any valves found to be fouled or defective because of foreign matter
left in the water line, and any subsequent damage, are not the responsibility of the
manufacturer.
A water hardness test must be performed. If water hardness is higher than 3 GPG,
install a water softener or install the optional Scale Prevention System (SPS). See the
next section and the Plumbing Options page for more information on the SPS.
If water hardness is higher than 3 GPG and a water softener is not being used, install
the SPS into the water line between the facility water line and machine water line.
Observe proper inlet/outlet water directions. A water shut-o󰀨 valve should be installed
before installing the SPS to allow access for service. The water supply must be
capable of the minimum “ow” pressure at the recommended temperature indicated
on the data plate.
Example
INSPECTION
UNPACKING
PLUMBING
A water hardness test
must be performed.
The plumber must ush
the incoming water line!
Shut-off
Valve
Adapter AdapterSPS Machine
Water Line
Facility
Water Line
*Adapters needed will vary.
i
Do not throw away
packaging if damage is
evident!