Electrical and grounding conductors must comply with the applicable portions of the
National Electric Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.
Refer to the data plate for machine operating requirements, machine voltage, total
amperage, and serial number.
Remove the back panel. Route power wires through indicated hole and connect to
power block and grounding lug. Install the service wires (L1 and L2) to the appropriate
terminals as they are marked below. Install the grounding wire into the lug provided.
It is recommended that “DE-OX” or another similar anti-oxidation agent be used on
all power connections.
Apply power to machine. Check incoming power at the terminal block and ensure it
corresponds with the voltage listed on the data plate. If not, contact a qualied service
agency to examine the problem. Do not run machine if voltage is too high or too low.
Shut-o the service breaker and advise all proper personnel of the location of the
breaker and any problems.
This is a commercial machine and reaches temperatures that can exceed those
generated by a residential machine. Surrounding countertops, cabinets, and ooring/
subooring material must be designed and/or selected with these higher temperatures
in mind.
Any damage to surrounding area that is caused by heat and/or moisture to materials
that are not recommended for higher temperatures will not be covered under warranty
or by the manufacturer.
INSTRUCTIONS
INSTALLATION
ELECTRICAL POWER
CONNECTIONS
Disconnect electrical
power at the breaker or
disconnect switch and
tag-out in accordance with
procedures and codes.
SURROUNDING
AREA
VOLTAGE CHECK
i
BACK
Hole
for
Wires
Power
Block