07610-004-64-85-A
3
OPERATING PARAMETERS
SPECIFICATIONS
Operating Capacity (without Load Time): HT-E
Racks per Hour 32
Dishes per Hour 800
Glasses per Hour 1152
Operating Capacity (with Load Time):
Racks per Hour 25
Dishes per Hour 625
Glasses per Hour 900
Tank Capacity (Gallons):
Wash Tank XX
Booster Tank XX
Electrical Loads (as applicable):
Wash Motor HP 3/4
Wash Heater kW (208 V) 3.2
Wash Heater kW (230 V) 4.5
Booster Heater kW (208 V) 3.9
Booster Heater kW (230 V) 5.5
Always refer to the machine data plate for specic electrical and water requirements.
The material provided on this page is for reference only and is subject to change
without notice.
Sound Level:
Workplace-related Emission Value (dBA) 66
Water Temperatures (°F):
Minimum Wash Temperature 150
Minimum Rinse Temperature 180
Minimum Incoming Water Temperature 110
Water Consumption:
Gallons per Rack 0.69
Gallons per Hour 22.1
Other Water Requirements:
Water Flow Pressure (PSI) 20 ± 5
Flow Rate Minimum (GPM) 4.6
Water Line Connection Size 3/4" GHT
Water Line Size (NPT) 1/2"
Drain Line Size (NPT) 1" ID
1 3/8" OD