FINAL TESTS
After you turn the power ON:
1. Check for proper voltage on pin 2 of any intercom line or jack in
a channel. It should read 26-30 Volts.
2. Test for proper operation of Call Signaling. Activate the Call
Signal on any beltpack or station. The call light on the Main
Station should illuminate and then go out when the call button is
released. If enabled, the Tone Alert should sound. Activate the
Call Signal on the Main Station. The call lights on any beltpacks
or stations should illuminate and then go out when the call
button is released.
3. Adjust the sidetone on this and all stations. (Refer to the manual
for each specific unit for instructions.) Using the headset or
panel mic, make sure that the Main Station can communicate
with attached beltpacks or stations. Check that other stations
can be heard through the panel speaker.
4. If connected, check that Program Input, Announce Output and
Hot Mic Output / IFB System jacks are functional. Verify the
operation of the controls that affect the function of these inputs
and outputs. Refer to the User Manual of the particular Main
Station.