P/N 57017, Rev. 3 Page 49
5 MAINTENANCE
5.1 Recommended lubricants
Lubricant
Brand
Where used
Gear grease
Polytac EP #2
Rotational drive, axial feed units
Light Oil
LPS 2
Unpainted surfaces
Cutting oil
UNOCAL KOOLKUT
Tool bits, work pieces
Hydraulic oil
Union UNAX AW32
Anti-wear hydraulic oil
Hydraulic motor
Anti-seize lubricant
Moly Grade Anti-seize
Jacking bolts
5.2 Boring bar/lead screw assembly
Clean the lead screw and boring bar frequently during operation. Keep chips away
from the lead screw threads. Lubricate the lead screw periodically with light oil to
ensure smooth travel of the tool carrier assembly. Before storage, lightly oil the bar to
prevent rusting. Do not grease the leadscrew.
5.3 Axial feed unit
Under normal conditions, the mechanical axial feed unit is maintenance free.
5.4 Rotational drive unit
The RDU has sealed lubrication. Under normal use, it is maintenance free.
5.5 Bearing support assembly
Before using the boring bar and periodically during long machining operations,
grease the bearings. Add grease slowly while the bar is rotating until a slight bead of
grease forms at the seals.
Periodically apply anti-seize to jacking bolts of the ID-mounting bearing.
5.6 Tool head assembly
5.6.1 Boring head assembly
Lightly oil all parts to prevent rusting.