46
If reporting to Group 3 is successful, Mobile Lite will terminate
reporting.
If reporting to Group 3 is unsuccessful (going through all the
Report Indexes within the group for 3 times), Mobile Lite will
also terminate reporting.
- When reporting to the first group failed (going through all the
Report Indexes within the group for 3 times), Mobile Lite will
start reporting to the next group. When reporting to the second
group succeeds, reporting is regarded as successful. If no
other group is programmed, Mobile Lite will stop reporting. If
there are more groups programmed, Mobile Lite will continue
reporting until all groups have been tried to complete the
reporting cycle.
- If reporting to all the programmed groups failed in a reporting
cycle, Mobile Lite will wait for 5 minutes. After 5 minutes,
Mobile Lite will retry as it starts another reporting cycle.
For Emergency event, Mobile Lite will try reporting for up to
three reporting cycles. If going through three reporting cycles
and all failed, Mobile Lite will terminate reporting.
Example 1, if Groups 1 and 3 are programmed for Emergency
reports, and assuming NO successful report until Group 1 is
successful after the second try:
Group 1 > Group 3 > Wait 5 minutes > Group 1 (Success!) >
Group 3 > Stops reporting whether Group 3 is successful or
not.
Example 2, if Groups 1 and 3 are programmed for Emergency
reports, and assuming there is NO successful report:
Group 1 > Group 3 > Wait 5 minutes > Group 1 > Group 3 >
Wait 5 minutes > Group 1 > Group 3 > Stops reporting
Status Events:
Mobile Lite will only go through one reporting cycle for Status
reports and will not retry if report failed.
For example, if Groups 1 and 3 are programmed for Status
reports:
Group 1 > Group 3 > Stops reporting