50
7. Appendix
7.1. SMS Remote Programming Commands Table
Item
Command
Example & Usage
Default
Make Unit
Scream
SCREAM
SCREAM:PROG,1111,60
To set the length of Mobile Lites beeping period (5-60 seconds) to
help the search for Mobile Lite when the device is lost
This command will also request for location information.
--
Locating via
SMS
LOC
LOC:PROG,1111,1
To locate Mobile Lite user via SMS
Parameter: 0 = No reply to senders mobile number
1 = Reply location to senders mobile number ,
--
Cellular
Module
Reset
RSTG
RSTG:PROG,1111
To reset Cellular Module
--
GPRS APN,
username &
password
APN
APN:PROG,1111,internet,,
To set GPRS APN, username and password (31 characters max. for
APN, 31 characters max. for username, 31 characters max. for
password)
APN: Internet
Username and
password:
empty
Report
settings
RPT
RPT:PROG,1111,1,0933111222,1,0,0,1
To configure report settings (index number, report destination, group,
type, miscellaneous and event filter)
Report Index: 1-5
Report destination: Depending on the reporting format
Group: 1-5
Type: 0 = Speech, 11 = CID_SIA_IP, 13 = SIA_CID_UDP, 18 =
AG_XML, 20= CID_SIA2_IP, 22= CID_SIA2_UDP, 30 = SMS_CID,
31 = SMS_TEXT
Miscellaneous: Enter 0 for this parameter
Event filter: 255 = all, 1 = status, 4 = emergency
No report
destination
Add Report
Event
EVAD
EVAD:PROG,1111,1100,0,200
To add a report event
Event: 1100, 1302, 3302, etc., The first digit 1=action, 3=restore
Group: 0
Zone: 200=Mobile Lite, 201-205=sensor zone
--
Keyword
setting
KEYWD
KEYWD:PROG,1111,IPOG
To set the keyword
15 characters max. for the keyword
PROG
Access
Code
ACCES
ACCES:PROG,1111,1,1234
To set the Access Code (index number, code)
8 digits max. for the Access Code
1111 for user 1
Guard time
settings
(normal and
fall sensor)
GUDT
GUDT:PROG,1111,10,15
To set the length of guard time periods (normal: __ seconds, fall
sensor: __ seconds)
Normal: 5 = 5 secs, 10 = 10 secs, 15 = 15 secs, 20 = 20 secs, 25 = 25
secs, 30 = 30 secs
Fall sensor: 5 = 5 secs, 10 = 10 secs, 15 = 15 secs, 20 = 20 secs, 25
= 25 secs, 30 = 30 secs
10
Factory
reset
FTSET
FTSET:PROG,1111
To execute a factory reset
--