B-19
Welding
GLC 353/503/553 MC3
- Select the required Welding current by turning
Potentiometer 1 on the wire drive operation panel.
The set welding current can be read on Display 2
on the power source.
- Begin welding.
Poti 1 Caution!
Protect eyes and skin against arc
radiation! Wear protective clothing !
- Carry out test welds and optimize the setting by
turning Potentiometer 1.
- The actual weld parameters voltage and current are
shown on Display 1 - position Volt -
and on Display 2 - position Ampere.
Note: If you select A
Hold
on Display 2 the maximum welding current used during
welding can be read at the end of the welding process.
B2.4 TIG Direct-Current