MAN.234 Rev.6 ENG - Use and maintenance manual S19HD page 48 of 126
is held pressed, the automatic closing of the aerial
part is activated.
The following maneuvers must be carried out up to
the limit switches in order:
o boom return up to 0°;
o turret rotation in the original direction up to ;
o pantograph descent up to 0°;
o boom lowering up to the support.
CAUTION! IF YOU MEET OBSTACLES
DURING THE AUTOMATIC CLOSURE OF
THE MACHINE, IMMEDIATELY RELEASE
THE BUTTON AND PROCEED WITH THE
MANUAL MANOEUVRES.
4.4.8 Acoustic warnings
During the use of the MEWP, it is possible to hear
the following acoustic warnings, corresponding to
the following signals:
SOUND
Corresponding to:
Continuous acoustic
signal (intermittent in
pre-alarm): when
exceeding the max-
imum load allowed.
Load limiter light activated
on basket control station
and on wired remote con-
trol.
Continuous acoustic
signal (intermittent in
pre-alarm): when
exceeding the max-
imum travel inclina-
tion allowed.
Maximum travel inclination
light activated on basket
control station and on wired
remote control.
Table 3: acoustic signals.
4.5 Lithium battery pack recharge
(*optional)
For full lithium version (*optional), in order to
recharge the battery pack, it will be necessary to
stall the machine.
Then operate according to the following procedure:
1. switch off the electric engine;
2. couple the 110/120/230 V plug (power line)
to the connector on the machine and press