MAN.234 Rev.6 ENG - Use and maintenance manual S19HD page 49 of 126
the appropriate button of the
magnetothermic switch;
3. now the batteries will be in charge and the
charge progress can be evaluated through
the leds on chassis box or on radio control
station.
The charge times are:
With a full charge (100%), the 160 Ah Eco-Battery
pack is able to perform at least 10 work cycles. A
work cycle includes the following sequence of op-
erations:
1) stabilization;
2) complete machine development;
3) complete machine return;
4) destabilization.
AT THE END OF EACH WORKING
SESSION AND HOWEVER AT LEAST
EVERY 15 DAYS, IF THE MEWP IS NOT
USED, ABSOLUTELY RECHARGE THE
BATTERY PACK.
4.6 Emergency manoeuvres
Before starting the emergency procedures, it
could be useful to contact C.M.C. Service
and communicate errors data.
In case of emergency, the controls of the MEWP
aerial part should be performed by the operator on
the ground.