MAN.234 Rev.6 ENG - Use and maintenance manual S19HD page 84 of 126
If an intervention that is different from the
following ones is necessary, ask the
C.M.C. Service for authorization and in-
structions.
8.1 Daily maintenance
All the following checks are to be per-
formed running the MEWP from the
emergency control station and without
anyone inside the basket.
Every day, before starting the MEWP, perform the
following operations:
Operations
If negative
result:
by
Check the level of the
hydraulic oil in the tank.
Top up
USER
Check the level of the
fuel in the tank.
Top up
USER
Check the level of the
coolant liquid.
Top up
USER
Check the batteries*
charge.
Charge or
replace
USER
Check the cleanliness
of the floor: oily or
greasy residues could
cause slipping.
Clean
USER
Check the wholeness of
the instruction and warn-
ing decals.
Replace
and/or in-
tegrate
USER
Operations
If negative
result:
by
Perform the following
testing operations by us-
ing the (emergency) con-
trols placed on the turret
when no one is aboard:
o stabilize the MEWP;
o lift and lower the tele-
scopic boom;
o lift and lower the jib;
o clockwise and coun-
terclockwise rotate
the turret;
o extend and withdraw
the telescopic boom.
It is
strictly for-
bidden to
use the
MEWP. Con-
tact the Ser-
vice.
C.M.C.

Related product manuals