MAN.234 Rev.6 ENG - Use and maintenance manual S19HD page 86 of 126
Check the functioning of
the moment limiter (if
present):
o stabilize the MEWP;
o load the basket with
220 Kg (only weights);
VERIFY THE ABSENCE
OF CRACKS AND
SPLITS ON ALL THE
STRUCTURE AND
WELDINGS OF MEWP.
During the check,
it is strictly forbidden to
load the MEWP placing
people in the basket.
o operate the levers for
the lifting and exten-
sion of the telescopic
boom until the max
outreach indicated in
work diagram.
THE MOMENT LIMITER
MUST START
INHIBITING ALL
OPERATIONS EXCEPT
It is
strictly for-
bidden to
use the
MEWP.
Contact the
Service.
C.M.C.
THOSE WHICH ALLOW
THE RETURN TO THE
WORK AREA.
Operations
If negative
result:
by
Check the functioning of
the block of the outrig-
gers when the aerial part
is developed:
o stabilize the MEWP;
o lift and extend the tel-
escopic boom;
O operate the levers of
outriggers control sta-
tion.
THE OUTRIGGERS
SHALL NOT MOVE.
It is
strictly for-
bidden to
use the
MEWP.
Contact the
Service.
C.M.C.
Check the functioning of
the block of the aerial
part when the MEWP is
not stabilized:
o set the MEWP in
transport position;
O operate the levers
of basket control sta-
tion to lift the aerial
part.
THE AERIAL PART
It is
strictly for-
bidden to
use the
MEWP.
Contact the
Service.
C.M.C.