MAN.219 Rev.8 ENG - Use and maintenance manual S19N page 48 of 71
work diagram.
THE MOMENT LIMITER MUST
START INHIBITING ALL
OPERATIONS EXCEPT THOSE
WHICH ALLOW THE RETURN TO
THE WORK AREA.
Check the functioning of the block
of the outriggers when the aerial
part is developed:
o stabilize the MEWP;
o lift and extend the telescopic boom;
O operate the levers of outriggers
control station.
THE OUTRIGGERS SHALL NOT
MOVE.
It is strictly
forbidden to use
the MEWP. Con-
tact the Service.
Check the functioning of the block
of the aerial part when the MEWP is
not stabilized:
o set the MEWP in transport position;
O operate the levers of basket
control station to lift the aerial part.
THE AERIAL PART SHALL NOT
MOVE.
It is strictly
forbidden to use the
MEWP. Contact the
Service.
In case of negative
result of the
checks:
Visually check the welds and
verify that there is no structural
failure.
It is strictly
forbidden to use the
MEWP. Contact the
Service.
Check the absence of splits,
cracks, rust on the MEWP struc-
ture.
It is strictly
forbidden to use the
MEWP. Contact the
Service.
Check that the safety devices
(emergency buttons, interlock
system for outriggers-boom) work
perfectly.
It is strictly
forbidden to use the
MEWP. Contact the
Service.
Check that the controls, the pilot
lights, the emergency buttons
work perfectly.
It is strictly
forbidden to use
the MEWP. Con-
tact the Service.
Check the wholeness of the cable
chains.
It is strictly
forbidden to use
the MEWP. Con-
tact the Service.