EasyManua.ls Logo

CMC S19N - 8.13 Consumables; 8.14 Indications for the dismantling of the MEWP

Default Icon
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAN.219 Rev.8 ENG - Use and maintenance manual S19N page 52 of 71
8.13 Consumables
Hydraulic oil:
(hydraulic tank capacity: 21 l)
Gazpromneft Hydraulic HDZ 32 o 46
32
46
Density, 15°C, kg/l
ASTM D4052
0,867
0,874
Kinematic Viscosity, 40°C, mm2/s
ASTM D445
32
46
Kinematic Viscosity, 100°C, mm2/s
ASTM D445
6,45
8,16
Viscosity Index
ASTM D2270
151
154
Pour point °C
ASTM D97
-42
-42
Flash point COC, °C
ASTM D92
216
228
A biodegradable hydraulic oil, called BIOHYDRAN TMP 46, can be sup-
plied as *optional:
Density, 15°C, kg/l
ASTM D4052
0,920
Kinematic Viscosity, 40°C, mm2/s
ASTM D445
46
Kinematic Viscosity, 100°C, mm2/s
ASTM D445
9,3
Viscosity Index
ASTM D2270
185
Pour point °C
ASTM D97
-42
Flash point COC, °C
ASTM D92
300
In case of refilling or replacement, it is imperative to use the
same hydraulic oil (or equivalent) and respect the technical
specifications of the product already present in the hydraulic
circuit.
Motor oil:
Texaco Motor Oil S 5W-40
Density, 15°C, kg/l
ASTM D4052
0,850
Kinematic Viscosity, 40°C, mm2/s
ASTM D445
76
Kinematic Viscosity, 100°C, mm2/s
ASTM D445
12,9
Viscosity Index
ASTM D2270
171
Pour point °C
ASTM D97
-43
Flash point COC, °C
ASTM D92
232
Grease:
for boom extension and outriggers:
Interflon Fin Grease LS1/2
Composition: mixture of mineral oils, calcium-lithium complex thick-
ener, additives and Teflon®. (working range: from -20°C to +120°C)
for fifth wheel, greasers, bearings, pins and supports:
ARTOS-BA NF 2
Composition: mixture of mineral oils and additives. NLGI 2 class.
(working range: from -20°C to +160°C)
Lubrificant:
for chains:
Interflon Fin Lube Ep Plus
Composition: mixture of mineral oils and vegetables, additives and
Teflon®.
Density at 20°C: 0,89 g/cm3
Kinematic Viscosity at 20°C (ASTM D2983): 380 mPa.
Before oil replacement, place an oil drip tray in order to avoid
the leakage of oil in the environment. Do not disperse the ex-
hausted oil or other consumables in the environment; put them
in the appropriate containers and give them to the authorized
collection centres.
8.14 Indications for the dismantling of the
MEWP
In the case of demolition, the machine is completely
dismantled according to the regulations in force.
The different types of materials should be distributed to the re-
spective authorized collection centers.