MAN.243 Rev.5 ENG - Use and maintenance manual S28 page 60 of 138
It is strictly forbidden to use the MEWP when
the load limiter device acoustic warning is on.
Remove the exceeding load from the basket
until the acoustic signal and the relative light
go out.
4.4.5.3 Slowdown of the aerial part
maneuvers
Slowdowns can be set by software for start and end of
each aerial part maneuver (lifting/lowering of booms,
extension/retraction of booms, clockwise/ anticlockwise
rotation of the turret, opening/closing jib), valid in the
following conditions:
o boom angle;
o boom extension;
o opening jib;
o pre-alarm condition (90% of the block);
o approaching the turret angle to a curve change
zone.
4.4.5.4 Anti-collision system
Since the machine can also work at negative heights, the
anti-collision system supplied prevents the basket and
booms from impacting with the outriggers, blocking the
activated movements.
However, it is possible to bypass this system by pressing
the parking button P on the left side of the radio control
(Picture 51).
Picture 51: P button to bypass
anti-collision system.