Recommended operation method Loading System MkII
40
Once an operative is wearing the correct harness they can then attach the 0.3
m extender to the harness by looping it through itself, and then attach the
other end of the extender to the Retractable Fall Arrest Block, using the
karabiner fixing.
The operative must be connected to the system before accessing
the flatbed.
Double Unit usage
A Double Unit is required, when loading and unloading a flatbed with a length
between 8 and 14 m, which will fit into the working zone as described in
Figure 35. A Double Unit consists of two Loading System MkII Base units with
two SkyReach Anchor units, two 10 m Falcon Fall Arrest Blocks, one full body
harness, two Top Column 4.7s (Art. 8809) or two SkyReach Adaptor 5.9s (Art.
8810), please see Figure 3 in the beginning of this document for visual
clarification of the parts.
This method is based on a width of the flatbed loading area greater or equal
to 2,4 m. By any width less than mentioned, or by flatbed length greater than
14 m, please contact Combisafe for advice.
The operative must be connected to both Loading System MkII units at the
same time before accessing the flatbed.
The Bases must be symmetrically positioned with respect to the loading zone
according to Figure 35 below.
Figure 35. Working area illustration for a Double Unit usage.
1. Loading Zone
2. Operative