Maintenance
Check list prior to usage
Checking of the system shall be performed before each use, if any of the
listed statements below are not met, make sure to correct any issue before
using the product.
Checking includes the following steps:
Loading System MkII Base unit:
Ensure that there is no weld damage or deformation to any part of the
system.
Ensure that no corrosion that can affect the strength of the system has
occurred.
Ensure that the Feet are fully adjustable.
Ensure that the Base unit is level.
Ensure there are no loose parts e.g. gravel, dirt, concrete etc. in any
sleeves or tubes where another part shall be inserted.
Ensure that the threads on the welding nuts on the Corner Posts are free
from dirt that can prevent correct fastening of the bolt. If not using the
Formwork Supports, short M12 bolts can be placed in the nuts to protect
the threads.
Ensure that there is no damage to the Precast Kentledge concrete block, if
such is used.
Ensure that all items with the insertion marking label on, are readable and
are inserted the correct length.
Ensure the legibility of the product marking.
Top Column 4.7 and SkyReach Adaptor 5.9:
Ensure that the item is inserted the correct length and that the insertion
marking label is readable.
Ensure that there is no weld damage or deformation to any part of the
item.
Ensure that no corrosion that can affect the strength of the item has
occurred.
Ensure the legibility of the Serial No. marking.