BUTTONS
AUDIO MODULE
• Button: select the button to program, referring to the images
• Function: this option is used to assign a dierent action to each module button
◊ None: no action (default)
◊ Light-me: this option is used to activate the LIGHT-ME function for the selected button
◊ Audio call: when the button is pressed, an audio call is made to the address entered in the “Address”
field (from 1 to 240). The “Number of calls” field also appears, in which you can select the number of
calls to make to the address entered in the “Address” field (System settings or from 1 to 10)
◊ Local output control: when the button is pressed, the output set in the “Output” field is activated (SE
output for the module or Relay output for the module)
◊ Actuator control: when the button is pressed, the actuator with the address entered in the “Address”
field is activated
◊ Control on Ultra bus (UDB): activates the relay on the Module keypad specified in the “Device type”
field (UDB output type: Relay 1 or Relay 2)
OUTPUTS
SE OUTPUT
• Function: select the command which activates the SE output for the audio module
◊ Lock-release: every lock-release command activates the output
◊ Actuator control: every actuator command with the address set in the “Address sent to external unit”
field activates the output
◊ Call sent: every call sent activates the output
• Activation
◊ Local output control (non-editable)
• Local output type
◊ SE (non-editable)
• Enable Tones: a confirmation tone is emitted when the output is activated for the time period set in the
“Activation time (sec.)” field
RELAY OUTPUT
• Function: select the command which activates the Relay output for the audio module
◊ Lock-release: every lock-release command activates the output
◊ Actuator control: every actuator command with the address set in the “Address sent to external unit”
field activates the output
◊ Call sent: every call sent activates the output
BUTTON MODULE TYPE
• Button module type: select the button module model, UT9200 (default) or 3063U
MODULES
• Button: select the button to program, referring to the images
• Function: this option is used to assign a dierent action to each module button
◊ None: no action (default)
◊ Audio call: when the button is pressed, an audio call is made to the address entered in the “Address”
field (from 1 to 240). The “Number of calls” field also appears, in which you can select the number of
calls to make to the address entered in the “Address” field (System settings or from 1 to 10)
◊ Local output control: when the button is pressed, the output set in the “Output” field is activated (SE
output for the module or Relay output for the module)
◊ Actuator control: when the button is pressed, the actuator with the address entered in the “Address”
field is activated
◊ Control on Ultra bus (UDB): activates the relay on the Module keypad specified in the “Device type”
field (UDB output type: Relay 1 or Relay 2)