Planning Information G8-S0/G3-S0-I
6 1.1/1010
Technical Data
Restrictions
The GE 800 and the GE 300 have 128 internal channels.
When using a G8-S0 / G3-S0-I, the max. number of internal channels decreases to 96.
One conversation requires:
4 channels for 16 kHz Audio
4 channels for 7 kHz Audio
4 channels for 3.5 kHz Audio
2 channels for 16 / 7 kHz All Calls/Radio Conferences/Music
1 channel for 3.5 kHz All Calls/Radio Conferences/Music
This results in:
24 conversations 16, 7 or 3.5 kHz
Note: A maximum of 48 radio conferences can be configured.
Download Restrictions
At download of the S0 card software the following restrictions apply:
Min. PRO 800 1.2
Min. CCT 800 1.2
The software can be downloaded to a maximum of 4 S0 cards simultaneously.
During the download, max. 9 cards (of any kind) may be inserted in the Intercom Server.
LED-Status Indication
Technical data G8-S0
Operating temperature range: 0°C to +50°C (32°F to +122°F)
Storage temperature range: -30°C to +60°C (-22°F to +140°F)
Relative humidity: 20% to 80%
Plug: 96-way pcb connector according DIN 41612
Power supply: from Intercom Server:
Emergency power consumption: 0,1 Ah/h
Measurements: 100 x 167 mm (3.94 x 6.58 inch)
Weight including package: G8-S0: 268 g (0.59 lbs), G3-S0-I: 224 g (0.49 lbs)
Number of conversations between two Intercom Servers: GE 800: max. 2 per G8-S0, GE 300: max. 1 per G3-S0-I