4-40
Compaq Professional Workstation AP550 Maintenance and Service Guide
Table 4-27
SCSI Test Names
Error Code Device
XX00-XX ID
XX05-XX Read
XX06-XX SA/Media
XX23-XX Random Read
XX28-XX Media load/unload
Table 4-28
SCSI Test Error Codes
Error Code Description Recommended Action
XXXX-02 Drive not installed Check cable connections.
XXXX-03 Media not in drive Check for and install DATA CD or
write-enabled tape in drive.
XXXX-05 Seek failure Replace the indicated device.
XXXX-06 Drive timed out Replace the indicated device.
XXXX-07 Drive busy Replace the indicated device.
XXXX-08 Drive already reserved Replace the indicated device.
XXXX-09 Unknown
XXXX-10 Unknown
XXXX-11 Media soft error Replace the indicated device.
XXXX-12 Drive not ready Replace the indicated device.
XXXX-13 Media error Replace the indicated device.
XXXX-14 Drive hardware error Replace the indicated device.
XXXX-15 Illegal drive command Replace the indicated device.
XXXX-16 Media was changed Replace the indicated device.
XXXX-17 Tape write-protected
1.
Disable write-protect on
tape cartridge.
2.
Replace tape drive.
XXXX-18 No data detected Replace the indicated device.
XXXX-21 Drive command aborted Replace the indicated device.
65XX-24 Media hard error
1.
Back up data and perform
Surface Analysis to
reallocate defect.
2.
Replace drive.