1205 - xx Auto answer Test
failed
1210 - xx Modem Direct Connect
Test failed
===========================================================================
Table 2-9. Hard Drive Test Error Codes
===========================================================================
Error
Code Description Recommended Action
===========================================================================
1701 - xx Hard drive format The following steps apply to 1701 - xx
test failed through 1736 - xx:
1702 - xx Hard drive read test 1. Run the Configuration and
failed Diagnostics Utilities and verify
drive type.
1703 - xx Hard drive write/read 2. Replace the hard drive signal and
/compare test failed power cables and retest.
3. Replace the hard drive controller
1704 - xx Hard drive random board and retest (if applicable).
seek test failed 4. Replace the hard drive and retest
(if applicable).
1705 - xx Hard drive controller 5. Replace the system board and retest.
test failed
1706 - xx Hard drive ready test
failed
1707 - xx Hard drive
recalibration test
failed
1708 - xx Hard drive format bad
track test failed
1709 - xx Hard drive reset
controller test
failed
1710 - xx Hard drive park head
test failed
1715 - xx Hard drive head
select test failed
1716 - xx Hard drive
conditional format
test failed
1717 - xx Hard drive ECC *
test failed
1719 - xx Hard drive power mode
test failed
1724 - xx Network preparation
test failed