6565
LED lamp check list
This is a check list for the LED lamps when the main unit is in operation
LED lamp display
Main unit operation
Details
Lights up in green
Recording in process
Recording in process
Flashes in green
Recording in process
Impact recording in process or manual recording in process
Lights up in orange
Recording stopped
Starting up
Setting mode in process
Play mode in process
Operation has stopped owing to thetemperature
of the main unit being too high or low
Flashes in orange
Recording stopped
Showing errors
Emergency recording stop
Flashing in green and
orange, alternately
Recording stopped
Updating main unit software
Error check list
When the following messages appear, check the handling methods.
Messages Handling methods
Please check the microSD card
,QFDVHVZKHUHDPLFUR6'+&FDUG KDVQRWEHHQ LQVHUWHGWXUQRႇ WKHSRZHU
then insert a microSDHC card and turn on the power.
7KHPLFUR6'+& FDUGPD\EH GDPDJHG7XUQRႇ WKHSRZHUUHPRYHWKHFDUG DQGFKHFNLIWKH
terminal parts are dirty. Then insert the card again and restart the unit. If the symptoms do not im
-
prove, try reformatting the card on a personal computer. In cases where there is no improvement,
WKHPLFUR6'+&FDUGVVHUYLFHOLIHPD\KDYHFRPHWRDQHQG5HSODFLQJWKHFDUGLVUHFRPPHQGHG
Caution for high temperatures
The recording and play functions have
been stopped owing to the temperature
of the main unit being too high
0DLQXQLW RSHUDWLQJWHPSHUDWXUHUDQJHKDVEHHQH[FHHGHGXQDEOH WRRSHUDWH
properly.To resume use, please wait a while for the temperature of the unit to
reach the operating temperature range.
Caution for low temperatures
The recording and play functions have
stopped owing to the temperature of the
main unit being too low
Event recording stopped
Recording area is full
This is an error displayed when overwriting prevention setting is set as [Event
recording] or [All recording] and recording that exceeds the microSDHC card
capacity is attempted.
Set the overwriting prevention setting to [OFF] or reformat the SD card and de
-
lete the recorded data.
Recording stopped
Recording area is full
* :KHUHWKHUHLVDQHUURULWZLOOEHGLVSOD\HGZLWKWKHDERYHPHVVDJHDQGWKH/('ODPSVZLOOÀDVKLQRUDQJH