UGC007/0702 Basic 32 Loader Control
DESCRIPTION 2-3
HOW IT WORKS
The B32 communicates with each pump, vacuum receiver and
material valve wired to Input/Output modules within the con-
trol enclosure. The B32 controls conveying operation based on
settings the operator enters on the HMI.
When receivers in a pump system demand material, the B32
turns on the vacuum pump and dust collector in the appropri-
ate pump system. It then opens the correct vacuum and mater-
ial valves to convey material to satisfy the demand.
The overview screen lets the operator monitor the status of all
vacuum receivers at a glance. Icons indicate the real-time sta-
tus of each receiver.
Other screens allow you to change system settings or to view
pump systems, loader details, alarm histories.