UGC007/0702 Basic 32 Loader Control
INSTALLATION 3-11
ENABLING
LOADERS
To enable the loaders from the main screen:
Use the Up/Down arrows to scroll to
Loader Settings.
Press the Enter arrow.
The Loader Settings screen displays. Use the
up/down arrows to scroll to Loader Enable.
Press the Enter arrow.
The Loader Enable screen displays. Use the
up/down arrows to increase and decrease the
loader number. Use the scroll down/up buttons to
enable/disable the loader.
1
2
3
To enable the pumps from the main screen:
Use the Up/Down arrows to scroll to
Loader Settings.
Press the Enter arrow.
The Loader Settings screen displays. Use the
up/down arrows to scroll to Pump Enable.
Press the Enter arrow.
The Pump Enable screen displays. Use the up/down
arrows to increase and decrease the pump number.
Use the scroll down/up buttons to enable/disable the
pump.
1
2
3
ENABLING
PUMPS