Thermolator TW Series UGH025-0504
D-2 APPENDIX
TW-1, TW-2 CONTROL SPI STATUS WORDS
Status, Process
Poll: 0x20 0x40
SPI STATUS WORD
Word BIT position 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
EEprom error SET SET
*
A/D converter error SET SET
*
CJC Error SET SET
*
RAM hardware SET SET
*
ROM checksum SET SET
*
Probe Failure SET SET
*
E/M Hi temp safety
*
Prog. Hi temp safety
*
Output monitor failure SET SET
*
Low water pressure SET SET SET
*
High deviation alarm SET SET SET
*
Low deviation alarm SET SET SET
*
Prog. Lo temp safety
*
Pump overload SET SET
*
Low water level SET SET
*
Test Mode
*
Phase error
*
NOTES:
*
The SPI I/O list defines the Processing bit as being cleared if the unit is not processing; otherwise it is SET.
Elsewhere on the chart:
l If a bit is not shown to be SET, it is cleared.
l The System Alarm bit is SET if an alarm is present. It is the logical OR of Process alarm and Machine alarm.
l Processing, System Alarm, Process Alarm and Machine Alarm bits are repeated for Process Status, Machine 1
Status and Machine 2 Status.
Open
Open
Reserved
Reserved
Reserved
Reserved
Alarm, Low flow
Reserved
Alarm, Low pressure condition
Alarm, High pressure condition
Alarm, Low temperature deviation
Alarm, High temperature deviation
Alarm, Machine
Alarm, Process
Alarm, System
Processing

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Conair Thermolator TW-1 and is the answer not in the manual?

Conair Thermolator TW-1 Specifications

General IconGeneral
BrandConair
ModelThermolator TW-1
CategoryControl Unit
LanguageEnglish

Related product manuals