76
10
DATA SHEET
10.1
TYPE
CLEAR SOFT Water softener
10.2
TECHNICAL SPECIFICATIONS
/ The water to be softened must conform to the European drinking water regulations!
/ The nominal pressure denotes the pressure class, to which the water softener must fulfil. The maxi-
mum operating pressure is lower, in order to ensure the optimum function of the water softener.
For further information, please refer to the chapter 10.3 “DIAGRAMS”.
Technical specification CLEAR SOFT
Connection diameter nominal DN 25 / 1"
Nominal capacity 0.45 mol
Capacity per kg regenerating salt 5 mol
Volume of exchanger resin approx. 2.5 l
Nominal pressure PN 10
Operating pressure 2 - 7 bar
Flow pressure at nominal flow rate min. 2 bar
Pressure loss at nominal flow rate 1 bar
Nominal flow rate 1,2 m³/h
Short-term flow max. 3,5 m³/h
Water consumption per regeneration approx. 12.5 l
Electrical connection 230 V / 50 Hz
Power consumption: Operation
Regeneration
2 W
max. 15 W
Water and ambient temperature max. 30 °C
Operating weight when filled with salt approx. 45 kg
Salt container capacity 25 kg
Shipping weight approx. 23 kg