EasyManua.ls Logo

Control Techniques FXM5 User Manual

Control Techniques FXM5
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
www.controltechniques.com
EF
User Guide
FXM5
Part Number: 0410-0011-05
Issue Number: 5
Question and Answer IconNeed help?

Do you have a question about the Control Techniques FXM5 and is the answer not in the manual?

Control Techniques FXM5 Specifications

General IconGeneral
BrandControl Techniques
ModelFXM5
CategoryInverter
LanguageEnglish

Summary

Safety Information

Introduction

Analog Control Mode Details

Control via variable speed drive monitoring armature voltage for field weakening.

Digital Control Mode Details

Control via Mentor II Drive for armature voltage and field current.

Internal Field Current Control Details

Setting field current at a fixed level using an internal potentiometer.

Installation

Mounting Instructions

Provides guidance on mounting the FXM5 controller vertically with proper clearance.

Cables and Fuses

Details recommended cable sizes, fuse ratings, and wiring practices for the FXM5.

Power Connections

AC Supply Connections

Instructions for connecting the AC supply, including using an alternative AC supply.

Armature Connections and Fuses

Armature Connection Types

Specifies how to make armature connections for different system control modes.

EMC Recommendations

Motor Cable EMC Requirements

Recommendations for motor cable shielding and grounding to meet EMC requirements.

Signal Connections

External Field Current Control Details

Details signal connections to terminal block TB1 for external field current control.

Setting Up

Setting Thyristor Control Mode

Procedure to set thyristor control mode (half or full control) using jumper LK3.

Setting the IFmax Value

Procedure to set the maximum field current (Ifmax) based on turns and jumper settings.

Setting Armature Voltage Range

Procedure for setting the armature-voltage range using jumper LK2.

Setting Maximum and Minimum Field Current

Procedure for setting maximum and minimum field current levels.

Setting Maximum Field Current

How to set maximum field current using SET MAX FIELD potentiometer.

Setting Minimum Field Current

How to set minimum field current using SET MIN FIELD potentiometer and TEST switch.

Adjusting Armature Voltage Threshold

Procedure to adjust armature voltage threshold for starting field weakening.

Fault Finding

Related product manuals