X-600M Users Manual Setup Pages
Name:
This is the file name to be used for the logged data.
Description:
A short description of the log file and the information contained within. The description will appear at
the top of the logX.txt files.
Location:
This field selects where you would like to save the logging data, either internally or on an external
USB storage device.
Start Time:
If a logging interval is specified (periodic logging rather than event logging), logging will occur
relative to this start time. For example, if the start time is 1:00AM and the logging rate is 6 hours,
logging will occur at 1:00AM, 7:00AM, 1:00PM, and 7:00PM. Start time is specified in a standard
time format.
Log Interval:
This field is used to specify the logging interval. A numerical value is entered into the text field, and
the interval is selected using the pull-down menu. The range of values in this field is 1-20864. Time
units are Minutes, Hours, and Days. Periodic logging can be disabled by selecting the Event
Logging Only option.
When Event Logging Only is chosen as the Log Interval, logging will only occur if an event and
action combination has been configured to log. For example, a conditional event can be configured
for whenever an input is on. An action can be configured to log whenever the previous event occurs.
See the sections on Conditional Events and Actions for more information.
Log File Contents:
This section has two windows. The window on the left lists the System I/O and Register resources
Xytronix Research & Design, Inc. Page 83