Service Handbook OEB/OES/OGB/OGS
AS/2013-01 6_02e_Updating the Control and Operation module software as of version 4_xx _d.doc
Page 3 / 3
loading is finished, uploading of the languages, texts and cookbooks begins.
This can take a few minutes.
9. When the display indicates the date and time again, the update has been
completed. Cut off the Convotherm from the power supply again.
10. Separate the PC / Laptop from the Control module again.
11. Plug the X12-connection into the Control module again.
12. Re-connect the power supply to the unit.
13. Perform a New-Init (Service point: C06) on the unit.
14. On the gas units, the unit specified burner speed must be readjusted (see
Service Handbook 6.25 Readjustment for the Gas Valve).
Notice:
The PC / Laptop requires a „real“ RS232 interface. If the Laptop doesn’t have
a RS232 interface ( Error Code „Can’t open COM-Port“), use a „PCMCIA
RS232“adaptor or a recommended „USB RS232“ part no. 5019200
adaptor.
In the field COM-Port, the correct COM-Port must be selected. (COM1,
COM2, ...)
No other programme should have access to the COM-Port during this time.
If you get the Error Code „Incorrect Start-file“ or „CRC-Error“ repeat the
upload. If this Error Code comes up again, there is probably a hardware
defect.
In the right window of the Update Programme, you will find advice as to how to
proceed.