Service Handbook OEB/OES/OGB/OGS
6.30.2 Roller replacement
Page 3 / 4
Check:
Door rattles when slid forwards and backwards.
Maintenance:
Keep guide rails and rollers clean.
Wipe the guide rails with an oiled cloth – do not use water spray!
Instructions - _Removing the slot panel:
Remove the door 1 (see Chapter 6.17.3 Outer door replacement) and place
it safely to the side.
Remove the covering 2 of the slot panel 4. Thereby, removing the two MLF
screws 3 and hang the covering upwards and out.
Remove the front and back stop buffer 5 on unit.
Loosen the 3 nuts M8 6 on the upper end of the slot panel 4 together with the
locker washer and carefully remove – hold the slot panel 4 securely.
Tilt the slot panel slightly away from the unit and remove the sliding block 7.
Tilt the slot panel 4 slightly away from the unit and pull forwards and out.
AS/11-2011 6_30e_Disappearing Door Replacement_Adjustment_b