24
COOLIUS A10
If the couplers are not joint to the stand or the coupler valves are not closed, Message:
9. Press START key to conrm.
The machine starts. The process cleans the complete
unit included the service hoses.
At the end,
10. Press STOP key at the end.
The machine is ready.
Join HP/LP couplers
to the stand and
close the valves!
Confirm by “START“
Internal flushing
end.
5.2 Fast service
1. Turn COOLIUS SELECT to select FAST SERVICE.
Press ENTER to conrm.
2. Turn COOLIUS SELECT to select the programs avail-
able:
• RECOVERY
• VACUUM / A/C SYSTEM CHARGE
3. Press ENTER to conrm.
Recovery
1. Turn COOLIUS SELECT to set the value.
• Minimum: 2 min.
• Maximum: 12 min.
2. Press ENTER to conrm.
The equipment performs the process.
Recovery, residual refrigerant check, used oil drain
process.
Vacuum / A/C system charge
1. Turn COOLIUS SELECT to set the vacuum time.
• Minimum: 0 min.
• Maximum: 999 min.
2. Press ENTER to conrm.
3. Turn COOLIUS SELECT to set the leak test time.
• Minimum: 2 min.
• Maximum: 60 min.
4. Press ENTER to conrm.
Fast Service
Recovery
Residual refrigerant
check.
min. 2
Vacuum time
min. 15
Leak test min. _